Photovoltaic input |
Maximum photovoltaic input voltage |
500 V |
Maximum photovoltaic power |
120 kW |
180 kW |
Mppt voltage range |
200 V ~ 500 V |
Number of MPPT |
2 |
3 |
|
|
Energy storage battery |
Cell type |
LFP 280 Ah |
Nominal voltage |
749 VDC |
Nominal power |
1.12 MWh (maintenance from the interior) 1.68 MWh (maintenance from the exterior) |
|
|
AC (on-grid) |
Maximum apparent power |
110 kVA |
165 kVA |
Rated output power |
100 kW |
150 kW |
Rate voltage |
400 V |
Voltage range |
320 V-460 V |
Maximum current |
144 A |
217 A |
Rated frequency |
50/60 Hz |
Frequency range |
45-55/55-65 Hz |
THDi |
<3% |
Power Factor |
1 leading ~ 1 lagging (settable) |
AC system |
3W+N+PE |
|
|
AC (off-grid) |
Rated voltage |
400 V |
THDU |
≤ 3% linear |
Rated frequency |
50/60 Hz |
Overload capacity |
110% long-term |
|
|
General data |
Maximum efficiency |
96.00% |
Degrees of protection |
IP55 |
Noise |
<65dB |
Ambient temperature |
-30 ℃~ +55 ℃ |
Cooling mode |
temperature controlled forced air cooling |
Relative humidity |
0 ~ 95% non condensing |
Altitude for product operation |
5000 m (Rating reduction occurs when the altitude for product application rises above 3000 m.) |
Battery compartment dimension (mm) |
6058*2438*2591 |
Isolation transformer |
available |
Self power consumption after system shut-down |
<500W |
|
|
Display |
Display |
TP LCD |
Bms communication interface |
RS485/CAN |
Local communication |
RS485/TCP/IP |
|
Reviews